Published October 2013 | Version v1
Journal article

Reliability assessment for thickness measurements of pipe wall using probability of detection

  • 1. Kobe Univ., Graduate School of System Informatics, Kobe, Hyogo (Japan)

Description

This paper proposes a reliability assessment method for thickness measurements of pipe wall using probability of detection (POD). Thicknesses of pipes are measured by qualified inspectors with ultrasonic thickness gauges. The inspection results are affected by human factors of the inspectors and include some errors, because the inspectors have different experiences and frequency of inspections. In order to ensure reliability for inspection results, first, POD evaluates experimental results of pipe-wall thickness inspection. We verify that the results have differences depending on inspectors including qualified inspectors. Second, two human factors that affect POD are indicated. Finally, it is confirmed that POD can identify the human factors and ensure reliability for pipe-wall thickness inspections. (author)

Additional details

Publishing Information

Journal Title
Hozengaku
Journal Volume
12
Journal Issue
3
Journal Page Range
p. 89-95
ISSN
1348-7795

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
45100557
Subject category
S42: ENGINEERING; S36: MATERIALS SCIENCE;
Descriptors DEI
DETECTION; HUMAN FACTORS; MEASURING METHODS; NUCLEAR POWER PLANTS; PIPES; PROBABILITY; RELIABILITY; THICKNESS; ULTRASONIC WAVES
Descriptors DEC
DIMENSIONS; NUCLEAR FACILITIES; POWER PLANTS; SOUND WAVES; THERMAL POWER PLANTS; TUBES

Optional Information

Notes
9 refs., 10 figs., 5 tabs.