Radiation exposure to patients from image guidance procedures and techniques to reduce the imaging dose

  • 1. Department of Radiation Oncology, Vanderbilt University School of Medicine, Nashville (United States)
  • 2. Varian Medical Systems, iLab GmbH, Baden-Dättwil (Switzerland)

Description

Purpose: To compare imaging doses from MV images, kV radiographs, and kV-CBCT and describe methods to reduce the dose to patient's organs using existing on-board imaging devices. Method and materials: Monte Carlo techniques were used to simulate kV X-ray sources. The kV image doses to a variety of patient anatomies were calculated by using the simulated realistic sources to deposit dose in patient CT images. For MV imaging, the doses for the same patients were calculated using a commercial treatment planning system. Results: Portal imaging results in the largest dose to anatomic structures, followed by Varian OBI CBCT, Varian TrueBeam CBCT and then kV radiographs. The imaging doses for the 50% volume from the DVHs, D50, to the eyes for representative head images are 4.3–4.8 cGy; 0.05–0.06 cGy; 0.04–0.05 cGy; and, 0.12 cGy; D50 to the bladder for representative pelvis images are 3.3 cGy; 1.6 cGy; 1.0 cGy; and, 0.07 cGy; while D50 to the heart for representative thorax images are 3.5 cGy; 0.42 cGy; 0.2 cGy; and, 0.07 cGy; when using portal imaging, OBI kV-CBCT scans, TrueBeam kV-CBCT scans and kV radiographs, respectively. The orientation of the kV beam can affect organ dose. For example, D50 to the eyes can be reduced from 0.12 cGy using AP and right lateral radiographs to 0.008–0.017 cGy when using PA and right lateral radiographs. In addition, organ exposures can be further reduced to 15–70% of their original values with the use of a full-fan, bow-tie filter for kV radiographs. In contrast, organ doses increase by a factor of ∼2–4 if bow-tie filters are not used during kV-CBCT acquisitions. Conclusion: Current on-board kV imaging devices result in much lower imaging doses compared to MV imagers even taking into account of higher bone dose from kV X-rays. And a variety of approaches are available to significantly reduce the image doses

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2013.05.034

Additional details

Identifiers

DOI
10.1016/j.radonc.2013.05.034;
PII
S0167-8140(13)00276-4;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
108
Journal Issue
1
Journal Page Range
p. 91-98
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45088263
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; COMPUTERIZED SIMULATION; CT-GUIDED RADIOTHERAPY; MONTE CARLO METHOD; PATIENTS; RADIATION DOSES
Descriptors DEC
CALCULATION METHODS; DIAGNOSTIC TECHNIQUES; DOSES; MEDICINE; NUCLEAR MEDICINE; RADIOLOGY; RADIOTHERAPY; SIMULATION; THERAPY

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.