Published 2001 | Version v1
Journal article

Proton magnetic resonance chemical shift imaging (1H CSI)-directed stereotactic biopsy

  • 1. Department of Neurosurgery, Kangnam St. Mary's Hospital, The Catholic University of Korea, Seoul (Korea, Republic of)
  • 2. Department of Radiology, Kangnam St. Mary's Hospital, The Catholic University of Korea, Seoul (Korea, Republic of)
  • 3. Department of Biomedical Engineering, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)
  • 4. Department of Radiology and Neurosurgery, Kyoto Perfectural University of Medicine, Kyoto (Japan)

Description

Introduction. To add metabolic information during stereotactic biopsy target selection, the authors adopted proton chemical shift imaging (1H CSI)-directed stereotactic biopsy. Currently, proton single voxel spectroscopy (SVS) technique has been reported in stereotactic biopsy. We performed 1H CSI in combination with a stereotactic headframe and selected targets according to local metabolic information, and evaluated the pathological results. Patients and Method. The 1H CSI-directed stereotactic biopsy was performed in four patients. 1H CSI and conventional Gd-enhancement stereotactic MRI were performed simultaneously after the fitting of a stereotactic frame. After reconstructing the metabolic maps of N-acetylaspartate (NAA)/phosphocreatine (Cr), phosphocholine (Cho)/Cr, and Lactate/Cr ratios, focal areas of increased Cho/Cr ratio and Lac/Cr ratios were selected as target sites in the stereotactic MR images. Result. 1H CSI is possible with the stereotactic headframe in place. No difficulty was experienced performing 1H CSI or making a diagnosis. Pathological samples taken from areas of increased Cho/Cr ratios and decreased NAA/Cr ratios provided information upon increased cellularity, mitoses and cellular atypism, and facilitated diagnosis. Pathological samples taken from areas of increased Lac/ Cr ratio snowed predominant feature of necrosis. Conclusion. 1H CSI was feasible with the stereotactic headframe in place. The final pathological results obtained were concordant with the local metabolic information from 1H CSI. We believe that 1H CSI-directed stereotactic biopsy has the potential to significantly improve the accuracy of stereotactic biopsy targeting. (author)

Additional details

Publishing Information

Journal Title
Acta Neurochirurgica
Journal Volume
143
Journal Page Range
p. 45-50
ISSN
0001-6268
CODEN
ACNUA5

INIS

Country of Publication
Austria
Country of Input or Organization
Austria
INIS RN
39072933
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOPSY; CHEMICAL SHIFT; HYDROGEN 1; METABOLISM; NMR IMAGING
Descriptors DEC
DIAGNOSTIC TECHNIQUES; HYDROGEN ISOTOPES; ISOTOPES; LIGHT NUCLEI; NUCLEI; ODD-EVEN NUCLEI; STABLE ISOTOPES

Optional Information

Notes
This record replaces 33011442