Proton magnetic resonance chemical shift imaging (1H CSI)-directed stereotactic biopsy
Creators
- 1. Department of Neurosurgery, Kangnam St. Mary's Hospital, The Catholic University of Korea, Seoul (Korea, Republic of)
- 2. Department of Radiology, Kangnam St. Mary's Hospital, The Catholic University of Korea, Seoul (Korea, Republic of)
- 3. Department of Biomedical Engineering, Kangnam St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)
- 4. Department of Radiology and Neurosurgery, Kyoto Perfectural University of Medicine, Kyoto (Japan)
Description
Introduction. To add metabolic information during stereotactic biopsy target selection, the authors adopted proton chemical shift imaging (1H CSI)-directed stereotactic biopsy. Currently, proton single voxel spectroscopy (SVS) technique has been reported in stereotactic biopsy. We performed 1H CSI in combination with a stereotactic headframe and selected targets according to local metabolic information, and evaluated the pathological results. Patients and Method. The 1H CSI-directed stereotactic biopsy was performed in four patients. 1H CSI and conventional Gd-enhancement stereotactic MRI were performed simultaneously after the fitting of a stereotactic frame. After reconstructing the metabolic maps of N-acetylaspartate (NAA)/phosphocreatine (Cr), phosphocholine (Cho)/Cr, and Lactate/Cr ratios, focal areas of increased Cho/Cr ratio and Lac/Cr ratios were selected as target sites in the stereotactic MR images. Result. 1H CSI is possible with the stereotactic headframe in place. No difficulty was experienced performing 1H CSI or making a diagnosis. Pathological samples taken from areas of increased Cho/Cr ratios and decreased NAA/Cr ratios provided information upon increased cellularity, mitoses and cellular atypism, and facilitated diagnosis. Pathological samples taken from areas of increased Lac/ Cr ratio snowed predominant feature of necrosis. Conclusion. 1H CSI was feasible with the stereotactic headframe in place. The final pathological results obtained were concordant with the local metabolic information from 1H CSI. We believe that 1H CSI-directed stereotactic biopsy has the potential to significantly improve the accuracy of stereotactic biopsy targeting. (author)
Additional details
Publishing Information
- Journal Title
- Acta Neurochirurgica
- Journal Volume
- 143
- Journal Page Range
- p. 45-50
- ISSN
- 0001-6268
- CODEN
- ACNUA5
INIS
- Country of Publication
- Austria
- Country of Input or Organization
- Austria
- INIS RN
- 39072933
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOPSY; CHEMICAL SHIFT; HYDROGEN 1; METABOLISM; NMR IMAGING
- Descriptors DEC
- DIAGNOSTIC TECHNIQUES; HYDROGEN ISOTOPES; ISOTOPES; LIGHT NUCLEI; NUCLEI; ODD-EVEN NUCLEI; STABLE ISOTOPES
Optional Information
- Notes
- This record replaces 33011442