Published September 1984 | Version v1
Journal article

The effect of apex-finding errors on factor images obtained from factor analysis and oblique transformation

Creators

  • 1. Royal Naval Hospital, Gosport (UK). Dept. of Nuclear Medicine

Description

The use of an oblique transformation to obtain physiological factors from a factor analysis of dynamic studies has recently been suggested. The technique involves using an apex-seeking routine to enable these factors and their contribution images to be formed. This paper investigates the effects of errors in apex-finding on these factor images. In particular it is shown that, apart from scaling, the factor image obtained from a given apex is independent of the position of that apex (and hence is independent of its own factor). (author)

Additional details

Publishing Information

Journal Title
Phys. Med. Biol.
Journal Volume
29
Journal Issue
9
Series
Phys. Med. Biol.
Journal Page Range
1109-1116
ISSN
0031-9155

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
16002440
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
DYNAMIC FUNCTION STUDIES; ERRORS; IMAGE PROCESSING; MATHEMATICAL MODELS