Tests in water of Superphenix pumps

  • 1. Electricite de France, 78 - Chatou

Description

The importance of primary and secondary pumps for the reliability and safety of the Superphenix fast breeder reactor led to the building of a facility allowing full scale tests of these pumps, but in water and not in sodium. After stating the reasons for such tests and describing the loop, the article considers the main lessons gained in the areas of technological design, mechanical behaviour and hydraulic performance

Abstract (French)

L'importance des pompes primaires et secondaires pour la fiabilite et la surete du reacteur a neutrons rapides Superphenix a conduit a construire une installation permettant de les essayer en vraie grandeur mais en eau et non en sodium. Apres une justification du bien-fonde de tels essais et une description de la boucle, l'article examine les principaux enseignements obtenus sur le plan de la conception technologique, du comportement mecanique et des performances hydrauliques