Published January 1993 | Version v1
Report

Fault trees of some systems at the Dukovany nuclear power plant for selected initiating event sequences

Description

Fault trees are presented for the primary circuit makeup and the boron control systems and for the technological water system at the Dukovany NPP. The fault trees were set up by employing the RISK SPECTRUM PSA code. The use of the two systems is described, and the apex events of the trees are defined. Analysis of the systems was performed. 15 figs., 19 refs

Availability note (English)

Available from Ustav jaderneho vyzkumu a.s., 250 68 Rez, Czech Republic.

Additional details

Additional titles

Original title (Czech)
Stromy poruch nekterych systemu JE Dukovany pro vybrane sekvence iniciacnich udalosti

Publishing Information

Imprint Pagination
43 p.
Report number
UJV--9861-T