Published October 2000 | Version v1
Journal article

The coupling calculation of 3-dimension cavity loop antenna

  • 1. Space Electronic Countermeasure Office, Electronic Engineering Inst., Hefei (China)
  • 2. Academia Sinica, Hefei (China). Inst. of Plasma Physics

Description

In ion cyclotron resonance heating, a 2-dimension antenna model is used for the cavity loop antenna with comparatively complex bounding conditions, neglecting the influence of loop antenna parallel component for simplicity. The detailed calculation process of a 3-dimension antenna model is given. This model is closer to the practical antenna, its calculation results can be used for the reference of antenna design

Additional details

Publishing Information

Journal Title
Acta Physica Sinica
Journal Volume
49
Journal Issue
10
Journal Page Range
p. 1978-1981
ISSN
1000-3290

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
32016950
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
ANTENNAS; BOUNDARY CONDITIONS; CAVITIES; COUPLING; ICR HEATING; MATHEMATICAL MODELS; THREE-DIMENSIONAL CALCULATIONS
Descriptors DEC
ELECTRICAL EQUIPMENT; EQUIPMENT; HEATING; HIGH-FREQUENCY HEATING; PLASMA HEATING