Published January 1983
| Version v1
Report
Open
Measurement and simulation of the drift pulses and resolution in the micro-jet chamber
Description
We have tested a prototype of a micro-jet chamber, using both a nitrogen laser and a 10GeV electron beam. The achieved resolution in the particle beam was sigma = 18μm for a lmm impact parameter and 22μm when averaging over the entire beam profile. The experimental results were compared to a Monte Carlo program which simulates the pulse shapes and resolution in drift chambers of any geometry. The main emphasis in our simulation analysis was to study various strategies for drift chambers in order to achieve the best possible timing resolution
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE83012334.Files
14788462.pdf
Files
(297.4 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:27569ab86690a29cb818502b5829eb99
|
297.4 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 16 p.
- Report number
- SLAC--PUB-3045
Conference
- Title
- Wire chamber conference.
- Dates
- 15-18 Feb 1983.
- Place
- Vienna (Austria).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14788462
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DRIFT CHAMBERS; ELECTRON BEAMS; GEV RANGE 01-10; MONTE CARLO METHOD; PARTICLE BEAMS; SIMULATION
- Descriptors DEC
- BEAMS; ENERGY RANGE; GEV RANGE; LEPTON BEAMS; MEASURING INSTRUMENTS; MULTIWIRE PROPORTIONAL CHAMBER; PROPORTIONAL COUNTERS; RADIATION DETECTORS
Optional Information
- Secondary number(s)
- CONF-830223--5.