Dose to sensitive organs due to scattered radiation during chest CT

  • 1. Universidad Autonoma de Zacatecas, Unidad Academica de Ingenieria Electrica, Programa de Doctorado en Ingenieria y Tecnologia Aplicada, 98060 Zacatecas, Zac. (Mexico)
  • 2. Universidad Autonoma de Zacatecas, Unidad Academica de Ingenieria Electrica, 98060 Zacatecas, Zac. (Mexico)
  • 3. Universidad Senor de Sipan, 14000 Chiclayo (Peru)

Description

The use of ionizing radiation for the treatment and diagnosis of diseases is more frequent. The technologies associated with diagnostic imaging are constantly evolving, allowing faster and cheaper diagnoses to benefit the patient. However, this has caused an increase in exposure to ionizing radiation for both patients and health professionals. One of the diagnostic techniques for obtaining high-resolution anatomical images of patients is computed tomography (CT). Due to the type, detail and quality of the images obtained with CT its use is becoming more frequent. The information provided by these images allows the specialist to make better diagnoses; however, exposure to X-rays deposits a dose in the patient. CT represents approximately 20% of all x-ray examinations; however, due to its characteristics, it is responsible for 70% of the medical dose accumulated by the patient. During the acquisition of the images, the highest dose is deposited in the area of the body whose image is to be obtained. During the incidence of X-rays there is dispersion of these that reach sensitive organs whose dose is not evaluated. The aim of this work was to estimate, using Monte Carlo methods, the dose to sensitive organs due to scattered radiation during chest CT. With the MCNP5 code the CT equipment and a hybrid anthropomorphic phantom, type BOMAB, with lenses, thyroid, mammary glands and reproductive organs were modeled. It was found that the absorbed dose in these organs depends on the size of the organ and the distance between the organ and the surface of the cut on the thorax where the X-rays are incident. (author)

Files

53114509.pdf

Files (1.4 MB)

Name Size Download all
md5:479b24de7ad50493e097e059f1d4f2d2
1.4 MB Preview Download

Additional details

Additional titles

Original title (Spanish)
Dosis en organos sensibles debida a la radiacion dispersada durante una TC de torax

Publishing Information

Publisher
Sociedad Mexicana de Irradiacion y Dosimetria
Imprint Place
Zacatecas, Zac. (Mexico)
Imprint Pagination
13 p.
Report number
INIS-MX--3562

Conference

Title
22. international symposium on solid state dosimetry
Acronym
ISSSD 2022
Dates
19-23 Sep 2022
Place
Zacatecas, Zac. (Mexico)