Published May 2004 | Version v1
Journal article

J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system

  • 1. Department of Radiology, National Defense Medical College, 3-2 Namiki, Tokorozawa, 359-0042, Saitama (Japan)
  • 2. Department of Radiology, Social Insurance Chuo General Hospital, Tokyo (Japan)

Description

The aim of this study was to verify the feasibility of using a J-tipped guidewire as a target for puncture of the subclavian artery in the placement of a reservoir port and catheter system (RPCS). Twenty-five patients with various hepatic malignancies underwent percutaneous implantation of an RPCS through the left subclavian artery for regional chemotherapy. To successfully puncture the left subclavian artery, a J-tipped guidewire was used as a target with fluoroscopic guidance. Technical success and complication rates, and numbers of puncture failures, were retrospectively analyzed. Implantation of the RPCS was successful in all patients. Eight (32%) patients had minor complications and no patient had major complications. The number of puncture failures per patient was 0 to 1 (mean=0.32). The J-tipped guidewire is a safe and appropriate target for puncture of the subclavian artery in the placement of an RPCS. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-003-2131-1

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
14
Journal Issue
5
Journal Page Range
p. 817-821
ISSN
0938-7994
CODEN