Published February 2004 | Version v1
Book

Flux mapping system for TAPP 3 and 4

  • 1. Electronics Division, Bhabha Atomic Research Centre, Mumbai (India)

Description

TAPP 3 and 4 reactor core requires on-line computation of the in-core flux profiles using a dedicated in-core Flux Mapping System (FMS). This system monitors the in-core detector signals located at different locations in the core and generates neutron flux profiles, 14 zonal powers and other related information. This information is generated using predefined matrices for known reactor states. The zonal powers generated by FMS are used to calculate the correction factors for the zonal powers as calculated by reactor regulating system and send these correction factors to reactor regulating system for computation of flux tilts and maintain required flux profiles. In order to meet the system requirements, redundant computer based Flux Mapping System with fault tolerant optical network connectivity is used. The paper describes the system requirements, system configuration, hardware used at different levels of the Flux Mapping system along with the dual fault tolerant optical link between various nodes of the system, and normal/diagnostic mode of operation of the system. (author)

Part of:
Proceedings of national symposium on nuclear instrumentation - 2004

Additional details

Publishing Information

Publisher
Board of Research in Nuclear Sciences
Imprint Place
Mumbai (India)
ISBN
81-88513-09-1
Imprint Title
Proceedings of national symposium on nuclear instrumentation - 2004
Imprint Pagination
758 p.
Journal Page Range
p. 147-152

Conference

Title
national symposium on nuclear instrumentation - 2004
Acronym
NSNI-2004
Dates
17-20 Feb 2004
Place
Kalpakkam (India)

Optional Information

Notes
1 ref., 1 fig.