CANFLEX fuel bundle cross-flow endurance test (test report)

Description

As part of the normal refuelling sequence of CANDU nuclear reactor, both new and irradiated bundles can be parked in the cross-flow region of the liner tubes. This situation occurs normally for a few minutes. The fuel bundle which is subjected to the cross-flow should be capable of withstanding the consequences of cross flow for normal periods, and maintain its mechanical integrity. The cross-flow endurance test was conducted for CANFLEX bundle, latest developed nuclear fuel, at CANDU-Hot Test Loop. The test was carried out during 4 hours at the inlet cross-flow region. After the test, the bundle successfully met all acceptance criteria after the 4 hours cross-flow test. (author). 2 refs., 3 tabs

Availability note (English)

Available from INIS in electronic form and/or on microfiche .

Files

29025592.pdf

Files (1.1 MB)

Name Size Download all
md5:4c8a1b47b2e12d9e5c680553c7272122
1.1 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
50 p.
Report number
KAERI/TR--903/97