UV sensitivity of various solid state detectors
Creators
- Knezevic, Zeljka1
- Ranogajec-Komor, Maria1
- Miljanic, Saveta1
- International Radiation Protection Association (IRPA), Fontenay-aux-Roses (France)
- Sociedad Argentina de Radioproteccion (SAR), Buenos Aires (Argentina)
- International Atomic Energy Agency (IAEA), Vienna (Austria)
- Pan American Health Organization (PAHO), Washington, DC (United States)
- World Health Organization (WHO), Geneva (Switzerland)
- 1. Institute Rudjer Boskovic, Zagreb (Croatia)
Description
Full text: The light sensitivity is an important characteristic of solid state passive dosimeters used in individual, clinical and environmental dosimetry. Light sensitivity stands for the response directly induced by visible or UV light in a fully annealed material. For the above mentioned applications a negligible light sensitivity is an advantage. However, high light sensitivity and linear response allows the use of detectors as UV dosimeters. For this purpose various TL detectors and the glass element of the RPL dosemeter type SC-1 were systematically investigated after exposure to UV light (254 and 366 nm) as a function of time. The following solid state detectors were investigated relative to TLD-100: Li2B4O7:Cu,Ag,P LiF:Mg,Cu,P, LiF:Mg,Cu,Si, Al2O3:C and the glass element of RPL dosimeter. UV irradiations were performed with Camag UV lamp at 254 nm and at 366 nm. The illumination times were 5, 10 and 20 minutes. Day light illumination was also carried out at room temperature over time period of several hours up to 2 weeks. The UV light response of each detector was compared to the response obtained after irradiation with 137Cs. Al2O3:C, showed high light sensitivity; after 10 minutes illumination with 254 nm UV light the response was equivalent to 130 mGy 137Cs gamma irradiation. The 254 nm UV response of LiF:Mg,Cu,P (GR-200 A), as well as TLD-700H and Li2B4O7:Cu,Ag,P were proportional to the time of illumination. The responses after 10 min UV illumination were equivalent to 0.001 mGy, 0.01 mGy and 0.1 mGy 137Cs gamma irradiation, respectively. The complete SC-1 RPL dosimeter is insensitive to light because the glass element is encapsulated in light protected holder throughout the automatic evaluation process following the annealing (irradiation, preheat, readout). The responses of the previously annealed glass element after 20 min illumination with 254 nm and 366 nm UV light were equivalent to 45μSv and 3 μSv of 137Cs gamma responses, respectively. The glass element itself could be used for 254 nm UV irradiation measurement. (author)
Files
42101891.pdf
Files
(112.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:958aab2abc88c3cc2d9c064f1ab814b1
|
112.3 kB | Preview Download |
Additional details
Publishing Information
- Publisher
- SAR
- Imprint Place
- Buenos Aires (Argentina)
- Imprint Pagination
- 1 p.
- Report number
- INIS-AR-C--1155
Conference
- Title
- 12. International Congress of the International Radiation Protection Association
- Acronym
- IRPA 12
- Dates
- 19-24 Oct 2008
- Place
- Buenos Aires (Argentina)
INIS
- Country of Publication
- Argentina
- Country of Input or Organization
- Argentina
- INIS RN
- 42101891
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALUMINIUM OXIDES; BORATES; CESIUM 137; GAMMA RADIATION; GLASS; LITHIUM FLUORIDES; RADIOSENSITIVITY; RPL DOSEMETERS; THERMOLUMINESCENT DOSEMETERS; ULTRAVIOLET RADIATION; VISIBLE RADIATION
- Descriptors DEC
- ALKALI METAL COMPOUNDS; ALUMINIUM COMPOUNDS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BORON COMPOUNDS; CESIUM ISOTOPES; CHALCOGENIDES; DOSEMETERS; ELECTROMAGNETIC RADIATION; FLUORIDES; FLUORINE COMPOUNDS; HALIDES; HALOGEN COMPOUNDS; INTERMEDIATE MASS NUCLEI; IONIZING RADIATIONS; ISOTOPES; LITHIUM COMPOUNDS; LITHIUM HALIDES; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; NUCLEI; ODD-EVEN NUCLEI; OXIDES; OXYGEN COMPOUNDS; RADIATIONS; RADIOISOTOPES; SENSITIVITY; YEARS LIVING RADIOISOTOPES
Optional Information
- Notes
- Abstract only