Review of design criteria for Criticality Accident Alarm System (CAAS) used in Fuel Reprocessing Facility

  • 1. Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

Description

Though fuel cycle facilities handling fissile materials are designed with careful criticality safety analysis, the criticality accident cannot be ruled out completely. Criticality Accident Alarm System (CAAS) is being installed as part of criticality safety management in fuel cycle facilities. CAAS system being used in India, is ECIL make, ionization chamber based gamma detector, which houses three identical detectors and works on 2/3 logic. As per ISO 7753 and ANSI/ANS-8.3, the CAAS must be designed to be capable of detecting any minimum accident occurs which could be of concern. Based on this, alarm limit used in CAAS is: 4 R/h (fast transient excursion) and 3 mR in 0.5 sec (slow excursion). In case of reprocessing facilities wherein process tanks located in heavy shielding, identification of CAAS installation locations require detailed radiation transport calculations. A study has been taken to estimate the gamma dose rate from thick concrete hot cells in order to determine the locations of CAAS to meet the present design criteria of alarm limit

Part of:
Proceedings of the international conference on radiological safety in workplace, nuclear facilities and environment: book of abstracts

Additional details

Publishing Information

Publisher
Indian Association for Radiation Protection
Imprint Place
Mumbai (India)
Imprint Title
Proceedings of the international conference on radiological safety in workplace, nuclear facilities and environment: book of abstracts
Imprint Pagination
287 p.
Journal Page Range
p. 261

Conference

Title
32. international conference on radiological safety in workplace, nuclear facilities and environment
Acronym
IARPIC-2016
Dates
22-25 Feb 2016
Place
Kalpakkam (India)

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
47088561
Subject category
S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALARM SYSTEMS; CRITICALITY; DESIGN; DOSE RATES; FUEL REPROCESSING PLANTS; HOT CELLS; RADIATION ACCIDENTS
Descriptors DEC
ACCIDENTS; EQUIPMENT; LABORATORY EQUIPMENT; NUCLEAR FACILITIES

Optional Information

Notes
2 refs., 2 figs.