Published 1989
| Version v1
Report
Open
Impurity studies in the advanced toroidal facility
Description
Impurities have played an important role in the initial stages of operation of the Advanced Toroidal Facility. Cleanup practices have been adequate enough that plasmas heated by ECH only can be operated in a quasi-steady state; however, neutral beam injected plasmas always collapse to a low temperature. It is not clear whether impurity radiation is actually responsible for initiating the collapse, but at the time the stored energy reaches a maximum, there are indications of poloidal asymmetries in radiation from low ionization stages, such as observed in marfes, which could play a dominant role in the plasma evolution. 3 refs., 5 figs
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 - OSTI; 1 as DE89006130.Files
20035734.pdf
Files
(157.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:41b05bb28006ee27748cae9b5a0bb772
|
157.0 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 4 p.
- Report number
- CONF-890302--5
Conference
- Title
- 16. European conference on controlled fusion and plasma physics.
- Dates
- 13-17 Mar 1989.
- Place
- Venice (Italy).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 20035734
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY; S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ATF TORSATRON; BEAM INJECTION HEATING; ECR HEATING; ELECTRON TEMPERATURE; IMPURITIES
- Descriptors DEC
- CLOSED PLASMA DEVICES; HEATING; HIGH-FREQUENCY HEATING; PLASMA HEATING; STELLARATORS; THERMONUCLEAR DEVICES; TORSATRON STELLARATOR
Optional Information
- Notes
- Portions of this document are illegible in microfiche products.