Published 1989 | Version v1
Report Open

Impurity studies in the advanced toroidal facility

Description

Impurities have played an important role in the initial stages of operation of the Advanced Toroidal Facility. Cleanup practices have been adequate enough that plasmas heated by ECH only can be operated in a quasi-steady state; however, neutral beam injected plasmas always collapse to a low temperature. It is not clear whether impurity radiation is actually responsible for initiating the collapse, but at the time the stored energy reaches a maximum, there are indications of poloidal asymmetries in radiation from low ionization stages, such as observed in marfes, which could play a dominant role in the plasma evolution. 3 refs., 5 figs

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 - OSTI; 1 as DE89006130.

Files

20035734.pdf

Files (157.0 kB)

Name Size Download all
md5:41b05bb28006ee27748cae9b5a0bb772
157.0 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
4 p.
Report number
CONF-890302--5

Conference

Title
16. European conference on controlled fusion and plasma physics.
Dates
13-17 Mar 1989.
Place
Venice (Italy).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
20035734
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY; S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ATF TORSATRON; BEAM INJECTION HEATING; ECR HEATING; ELECTRON TEMPERATURE; IMPURITIES
Descriptors DEC
CLOSED PLASMA DEVICES; HEATING; HIGH-FREQUENCY HEATING; PLASMA HEATING; STELLARATORS; THERMONUCLEAR DEVICES; TORSATRON STELLARATOR

Optional Information

Notes
Portions of this document are illegible in microfiche products.