Published December 1993 | Version v1
Journal article

The design of integrated intermediate heat exchanger/system generator

  • 1. Qinghua Univ., Beijing, BJ (China). Inst. of Nuclear Energy Technology

Description

Intermediate heat exchanger (IHX) and Steam Generator (SG) for 10 MW MHTGR test model are contained in a pressure vessel. Integrated arrangement is adopted to increase safety and economy of test model. The authors describe design concept and structure features of integrated IHX/SG

Additional details

Publishing Information

Journal Title
Chinese Journal of Nuclear Science and Engineering
Journal Volume
13
Journal Issue
4
Series
A Supplemet to the volum; Special Issue of HTGR (Part 1).
Journal Page Range
p. 134-140.
ISSN
0258-0918
CODEN
HYGODG