Published 1990 | Version v1
Journal article

Calculated backscatter from phantoms for photon dosemeter calibration

  • 1. National Radiological Protection Board, Chilton (UK)

Description

Results are presented of calculations of the backscattered radiation field at the surface of the ICRU sphere as reference phantom and of proposed calibration phantoms MS20 and PMMA as 30 cm sphere, 30 cm cube and 30 x 30 x 15 cm3 slab. For comparison purposes, calculations were also made for phantoms of ICRU tissue as 30 cm cube and 30 x 30 x 15 cm3 slab. The backscattered radiation fields at the surface of 30 x 30 x 15 cm3 slab phantoms are close to those for 30 cm cube phantoms of the same material. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
32
Journal Issue
2
Series
Radiat. Prot. Dosim.
Journal Page Range
123-125
ISSN
0144-8420
CODEN
RPDOD