Published September 1975 | Version v1
Miscellaneous

Irradiation probe and laboratory for irradiated material evaluation

Description

The survey and assessment are given of the tasks carried out in the years 1971 to 1975 within the development of methods for structural materials irradiation and of a probe for the irradiation thereof in the A-1 reactor. The programme and implementation of laboratory tests of the irradiation probe are described. In the actual reactor irradiation, the pulse tube length between the pressure governor and the irradiation probe is approximately 20 m, the diameter is 2.2 mm. Temperature reaches 800 degC while the pressure control system operates at 20 degC. The laboratory tests (carried out at 20 degC) showed that the response time of the pressure control system to a stepwise pressure change in the irradiation probe from 0 to 22 at. is 0.5 s. Pressure changes were also studied in the irradiation probe and in the entire system resulting from temperature changes in the irradiation probe. Temperature distribution in the body of the irradiation probe heating furnace was determined. (B.S.)

Availability note (English)

Available from Atomova elektraren Bohunice, Jaslovske Bohunice, Czechoslovakia.

Additional details

Additional titles

Original title (Slovak)
Ozarovacia sonda a laboratorium pre vyhodnocovanie oziarenych materialov

Publishing Information

Imprint Pagination
57 p.
Report number
CS-INIS--76