Published 1996 | Version v1
Journal article

Improved set of criticality accident detectors used in the intercomparison experiment in Valduc

  • 1. Inst. of Atomic Energy, Otwock-Swierk (Poland)

Description

An improved set of critically accident detectors has been elaborated for the needs of the Inst. of Atomic Energy in Swierk. The sets, which consist of fission track detectors, wide-base silicon diodes and RPL glasses, were tested in the international intercomparison experiment in Valduc, France. Comparison of our results with the reference measurements showed a good agreement (within 25%) for both the neutron and gamma measurements. Additionally, the diode response to neutron kerma was investigated more extensively in the dose range between 2 and 10 Gy, where the dependence of the diode signal versus neutron kerma was not well known. A possibility of the multiple use of the diodes has been proved. (author)

Additional details

Publishing Information

Journal Title
Polish Journal of Medical Physics and Engineering
Journal Volume
2
Journal Issue
6
Journal Page Range
p. 181-191
ISSN
1425-4689

Optional Information

Notes
14 refs, 2 figs, 3 tabs