Published 1995 | Version v1
Report Open

In-bed accountability of tritium in production scale metal hydride storage beds

Description

An ''in-bed accountability'' (IBA) flowing gas calorimetric measurement method has been developed and implemented to eliminate the need to remove tritium from production scale metal hydride storage beds for inventory measurement purposes. Six-point tritium IBA calibration curves have been completed for two, 390 gram tritium metal hydride storage beds. The calibration curves for the two tritium beds are similar to those obtained from the ''cold'' test program. Tritium inventory errors at the 95 percent confidence level ranged from ± 7.3 to 8.6 grams for the cold test results compared to ± 4.2 to 7.5 grams obtained for the two tritium calibrated beds

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95006459; NTIS; US Govt. Printing Office Dep.

Files

26048051.pdf

Files (675.4 kB)

Name Size Download all
md5:14ed8786238ba670b67b7b28d7055686
675.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
24 p.
Report number
WSRC-MS--94-0489

Conference

Title
5. topical meeting on tritium technology in fission, fusion and isotopic applications.
Dates
28 May - 3 Jun 1995.
Place
Ispra (Italy).

Optional Information

Contract/Grant/Project number
Contract AC09-89SR18035
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)
CONF-950506--1.