Published November 1984
| Version v1
Report
Error sources involved in radiochemical processing
Description
Error sources typical for radiochemical processing in destructive neutron activation analysis of biomedical samples are discussed. Main aspects considered are: transfer of the irradiated sample from the irradiation container, addition of carrier, mineralization, chemical separation, determination of the chemical yield, calibration standards, blank correction, and contamination control. (author)
Additional details
Publishing Information
- Imprint Title
- Quality assurance in biomedical neutron activation analysis
- Imprint Pagination
- 205 p.
- Journal Page Range
- p. 153-161.
- Report number
- IAEA-TECDOC--323
Conference
- Title
- Advisory group meeting on quality asssurance in biomedical neutron activation analysis.
- Dates
- 13-17 Sep 1982.
- Place
- Vienna (Austria).
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 16026152
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BIOLOGICAL MATERIALS; CALIBRATION STANDARDS; CHEMICAL REACTION YIELD; ELEMENTS; ERRORS; IMPURITIES; NEUTRON ACTIVATION ANALYSIS; RADIOCHEMISTRY; SAMPLE PREPARATION; SEPARATION PROCESSES; TRACE AMOUNTS
- Descriptors DEC
- ACTIVATION ANALYSIS; CHEMICAL ANALYSIS; CHEMISTRY; MATERIALS