Published October 2013 | Version v1
Journal article

Evaluating ITER remote handling middleware concepts

  • 1. FOM Institute DIFFER, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands)
  • 2. Heemskerk Innovative Technology, Noordwijk (Netherlands)
  • 3. University of Applied Sciences InHolland, Alkmaar (Netherlands)
  • 4. ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

Description

Highlights: ► Remote Handling Study Centre: middleware system setup and modules built. ► Aligning to ITER RH Control System Layout: prototype of database, VR and simulator. ► OpenSplice DDS, ZeroC ICE messaging and object oriented middlewares reviewed. ► Windows network latency found problematic for semi-realtime control over the network. -- Abstract: Remote maintenance activities in ITER will be performed by a unique set of hardware systems, supported by an extensive software kit. A layer of middleware will manage and control a complex set of interconnections between teams of operators, hardware devices in various operating theatres, and databases managing tool and task logistics. The middleware is driven by constraints on amounts and timing of data like real-time control loops, camera images, and database access. The Remote Handling Study Centre (RHSC), located at FOM institute DIFFER, has a 4-operator work cell in an ITER relevant RH Control Room setup which connects to a virtual hot cell back-end. The centre is developing and testing flexible integration of the Control Room components, resulting in proof-of-concept tests of this middleware layer. SW components studied include generic human-machine interface software, a prototype of a RH operations management system, and a distributed virtual reality system supporting multi-screen, multi-actor, and multiple independent views. Real-time rigid body dynamics and contact interaction simulation software supports simulation of structural deformation, "augmented reality" operations and operator training. The paper presents generic requirements and conceptual design of middleware components and Operations Management System in the context of a RH Control Room work cell. The simulation software is analyzed for real-time performance and it is argued that it is critical for middleware to have complete control over the physical network to be able to guarantee bandwidth and latency to the components

Availability note (English)

Available from http://dx.doi.org/10.1016/j.fusengdes.2013.02.028

Additional details

Identifiers

DOI
10.1016/j.fusengdes.2013.02.028;
PII
S0920-3796(13)00142-7;

Publishing Information

Journal Title
Fusion Engineering and Design
Journal Volume
88
Journal Issue
9-10
Journal Page Range
p. 2146-2150
ISSN
0920-3796
CODEN
FEDEEE

Conference

Title
27. symposium on fusion technology
Acronym
SOFT-27
Dates
24-28 Sep 2012
Place
Liege (Belgium)

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45053987
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPUTER CODES; CONTROL ROOMS; CONTROL SYSTEMS; DESIGN; HOT CELLS; ITER TOKAMAK; MAINTENANCE; MAN-MACHINE SYSTEMS; PERFORMANCE; REMOTE HANDLING; SIMULATION; SIMULATORS
Descriptors DEC
ANALOG SYSTEMS; CLOSED PLASMA DEVICES; EQUIPMENT; FUNCTIONAL MODELS; LABORATORY EQUIPMENT; THERMONUCLEAR DEVICES; THERMONUCLEAR REACTORS; TOKAMAK DEVICES; TOKAMAK TYPE REACTORS

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.