Published May 12, 2004 | Version v1
Journal article

Present status of a high-resolution soft x-ray monochromator at BL27SU in SPring-8

  • 1. SPring-8/JASRI, 1-1-1 Kouto, Mikazuki-cho, Sayo-gun, Hyogo 679-5198 (Japan)
  • 2. SPring-8/RIKEN, 1-1-1 Kouto, Mikazuki-cho, Sayo-gun, Hyogo 679-5148 (Japan)

Description

The output energy and resolving power of a high-resolution monochromator are sensitive to temperature and vibrations of optical elements. Cooling of mirrors and gratings require: (1) to decreasing the velocity of cooling water with sufficient flow rate, (2) positioning devices to avoid distortion by cooling tube, and (3) maintaining an intimate contact with plates for exhausting heat. We have installed a cooling system that fulfills these essential conditions by using InGa in the monochromator of BL27SU, so that its energy drift is decreased to 10 meV for 6 hours

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
705
Journal Issue
1
Journal Page Range
p. 667-670
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
8. international conference on synchrotron radiation instrumentation
Dates
25-29 Aug 2003
Place
San Francisco, CA (United States)

Optional Information

Notes
(c) 2004 American Institute of Physics