Published 1986 | Version v1
Report Restricted

Standards for pressure drop testing of filters as applied to HEPA filters

Description

A study has been made of the pressure drop testing performed by three filter test facilities for the Department of Energy. The testing is performed for both pressure drop and filter efficiency to assure that the filters meet specifications for use in the nuclear industry. It is shown that serious errors in pressure drop testing can occur if mass flow rates are used without correcting the pressure drop to a standard condition. Several alternatives are given for testing methods, including use of volume flow rates or laminar flow meters as testing standards. Similar standards should be considered for general filter pressure drop testing

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE86008967.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
17 p.
Report number
K/PS--5070

Conference

Title
Symposium on fluid filtration.
Dates
20-22 Oct 1986.
Place
Philadelphia, PA (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
18052117
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
FILTERS; FLOW RATE; FLUID FLOW; PERFORMANCE; PRESSURE DROP; QUALITY ASSURANCE; SPECIFICATIONS; TEST FACILITIES; TESTING

Optional Information

Secondary number(s)
CONF-861060--1.