Published September 1984 | Version v1
Journal article

Detection of breast carcinoma: comparison of automated water-path whole-breast sonography, mammography, and physical examination

  • 1. Emory Univ. Clinic, Atlanta, GA

Description

A comparative study of independently conducted physical examination, x-ray mammography, and sonography of the breast was carried out on 786 women having 77 excisional biopsies with 31 proven breast carcinomas. On breast sonography, 68% of the carcinomas were demonstrated with three false-positive diagnoses, compared with 65% cancer detection rate on physical examination with 37 false postives, and 77% detection rate on mammography with 15 false positives. Sonography was considered complementary to the other methods and of distinct usefulness after mammography 1) to examine the dense breast; 2) to study dense, poorly demonstrated areas; 3) to differentiate cystic from solid masses; and 4) to study breasts with augmentation mammoplasties

Additional details

Publishing Information

Journal Title
AJR, Am. J. Roentgenol.
Journal Volume
143
Journal Issue
3
Series
AJR, Am. J. Roentgenol.
Journal Page Range
493-497
ISSN