Published 1987 | Version v1
Book

Seismic qualification of nuclear control board by using base isolation technique

  • 1. Mitsubishi Electric Corp., Amagasaki, Hyogo (Japan). Central Research Lab.
  • 2. Tokyo Univ. (Japan). Inst. of Industrial Science

Description

The purpose is to adopt base isolation technique as a new approach for seismic qualification of nuclear control board. Basic concept of base isolation technique is expressed. Two dimensional linear motion mechanism with pre-tensioned coil springs and some dampers are included in the isolation device. Control board is regarded as a lamped mass system with inertia moment. Fundamental movement of this device and control board is calculated as a non-linear response problems. Fundamental analysis and numerical estimation, experimental investigation has been undertaken using an actual size control board. Sufficient agreement was recognized between experimental results and numerical estimation. (orig./HP)

Additional details

Publishing Information

Publisher
Balkema.
Imprint Place
Rotterdam (Netherlands)
ISBN
90-6191-772-7
Imprint Title
Transactions of the 9th international conference on structural mechanics in reactor technology. Vol. K2
Imprint Pagination
669 p.
Journal Page Range
p. 693-698.

Conference

Title
9. biennial international conference on structural mechanics in reactor technology (SMIRT-9).
Dates
17-21 Aug 1987.
Place
Lausanne (Switzerland).

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
19045868
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CONTROL EQUIPMENT; CONTROL ROOMS; DAMPING; EARTHQUAKES; ELECTRICAL EQUIPMENT; ELECTRONIC EQUIPMENT; FASTENERS; REACTOR COMPONENTS; REACTOR CONTROL SYSTEMS; RESPONSE FUNCTIONS; SEISMIC EFFECTS; SUPPORTS
Descriptors DEC
CONTROL SYSTEMS; EQUIPMENT; FUNCTIONS; MECHANICAL STRUCTURES