Analysis and study on the performance variation of SCR DeNOx catalyst of Coal-Fired Boilers

  • 1. Shanghai University of Electric Power, Shanghai 200090 (China)

Description

Nitrogen oxides (NOx) are one kind of harmful substances from the burning process of fossil fuel and air at high temperature. NOx emissions cause serious pollution on atmospheric environment. In this paper, coal-fired utility boilers were chosen as the object, NOx formation mechanism and control were studied, and SCR deNOx technology was used to control NOx emissions from coal-fired boilers. Analyzed the relationship between deNOx efficiency and characteristics of SCR DeNOx catalyst. Through analysis, affecting SCR DeNOx catalyst failure factors, change law of catalytic properties and technical measures to extend the service life of the catalyst were gotten. (author)

Availability note (English)

Available in Malaysian Nuclear Agency Document Delivery Center by email: mohdhafizal@nuclearmalaysia.gov.my.

Additional details

Publishing Information

Imprint Pagination
7 p.

Conference

Title
The 6th International Conference on Combustion, Incineration/ Pyrolysis and Emission Control: Waste to Wealth
Acronym
ICIPEC 2010
Dates
26-29 Jul 2010
Place
Kuala Lumpur (Malaysia)

INIS

Country of Publication
Malaysia
Country of Input or Organization
Malaysia
INIS RN
42047400
Subject category
S54: ENVIRONMENTAL SCIENCES; S01: COAL, LIGNITE, AND PEAT;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
BOILERS; CATALYSTS; COAL; GREENHOUSE GASES; NITROGEN OXIDES; POLLUTION; STRUCTURAL CHEMICAL ANALYSIS
Descriptors DEC
CARBONACEOUS MATERIALS; CHALCOGENIDES; ENERGY SOURCES; FOSSIL FUELS; FUELS; MATERIALS; NITROGEN COMPOUNDS; OXIDES; OXYGEN COMPOUNDS

Optional Information

Notes