Published January 1, 1989
| Version v1
Journal article
Comparison of muon and pion capture ratios in H2-Ar gas mixtures
Creators
- 1. Institut de Physique de l'Universite, CH-1700 Fribourg, Switzerland
Description
The muonic Coulomb capture ratio A(H2,Ar) has been measured in two different H2-Ar gas mixtures using two different methods of evaluation based on the muon transfer from hydrogen. The measured ratios agree with each other, but disagree with the corresponding pionic capture ratio and also with the ratios calculated from muonic and pionic A(He,Ar) and A(He,H2) capture ratios. The large discrepancies might be related to unsolved problems in muon transfer
Additional details
Publishing Information
- Journal Title
- Physical Review, A
- Journal Volume
- 39
- Journal Issue
- 1
- Series
- Phys. Rev., A.
- Journal Page Range
- 387-390
- ISSN
- 0556-2791
- CODEN
- PLRAA
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 20024139
- Subject category
- S74: ATOMIC AND MOLECULAR PHYSICS;
- Descriptors DEI
- ARGON; BINARY MIXTURES; CHARGE EXCHANGE; COMPARATIVE EVALUATIONS; GASES; HYDROGEN; MUONIC ATOMS; MUONS; PANOFSKY RATIO; PIONS; QUANTITY RATIO; X-RAY SPECTRA
- Descriptors DEC