Biodegradable device applied in flatfoot surgery: Comparative studies between clinical and technological aspects of removed screws

  • 1. Department of Life Sciences, University of Modena and Reggio Emilia, Via Campi 183, 41100 Modena, MO (Italy)
  • 2. Orthopaedic and Traumatologic Clinic, University Hospital of Modena and Reggio Emilia, Modena Italy, Director Prof. F. Catani, Via del Pozzo 71, Policlinico, 41100 Modena, MO (Italy)
  • 3. CIGS, University of Modena and Reggio Emilia, Via Campi 213/A, 41100 Modena, MO (Italy)
  • 4. Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Via del Pozzo 71, Policlinico, 41100 Modena, MO (Italy)

Description

Poly-L-lactide (PLLA) is one of the most used polymers for biomedical application; its use in sutures and other implants has been widely investigated. Although the knowledge of PLLA biodegradation and biocompatibility features is deep, PLLA screws used to correct the flat foot deformity have deserved attention since they are not degraded in most of cases after a long period of years (3–7) from the implantation. In this article, a clinical and radiological evaluation (NMR, histological and clinical outcomes) on patients was correlated with physico-chemical characterization (by SEM, DSC, GPC and XRD analysis at different temperatures) on both native and patient-recovered screws together with the theoretical degradation processes of PLLA-based implants. The data demonstrated the need for crossing the biodegradation and bioabsorption of the polymer with the characteristics of both the device (geometry, structure and fabrication process) and the implantation site. Highlights: ► Resorbable PLLA screws were proposed for arthroereisis in pediatric flatfoot. ► Satisfactory clinical results were obtained almost in the totality of patients. ► The bioabsorption period is slightly longer than what is expected. ► Patient-recovered screws were analyzed to evaluate the biodegradation stage. ► Degradability/structural integrity during implantation should be ameliorated

Availability note (English)

Available from http://dx.doi.org/10.1016/j.msec.2012.12.093

Additional details

Identifiers

DOI
10.1016/j.msec.2012.12.093;
PII
S0928-4931(13)00006-4;

Publishing Information

Journal Title
Materials Science and Engineering. C, Biomimetic Materials, Sensors and Systems
Journal Volume
33
Journal Issue
3
Journal Page Range
p. 1773-1782
ISSN
0928-4931

INIS

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.