Published September 2012 | Version v1
Journal article

The use of solid angle for alpha detector efficiency in 226Ra analyses of soil samples

  • 1. Turkish Atomic Energy Authority, Sarayköy Nuclear Research and Training Saray Mah., Atom Cad. No. 27, 06983 Kazan, Ankara (Turkey)
  • 2. European Commission, Joint Research Centre, Institute for Reference Materials and Measurements, Retieseweg 111, B-2440 Geel (Belgium)

Description

In the frame of proficiency tests organized by IAEA and IRMM, the specific activity concentration of radium-226 in soil has been measured. The BaSO4 co-precipitation technique has been used. Normally, in this method, the detector efficiency of the alpha spectrometer is determined using a 226Ra source with known activity. As an alternative to using a 226Ra standard, we calculated the detector efficiency from the relative solid angle subtended by the detector on the soil samples. The accuracy of this method depends on the uncertainty of geometrical properties and the distribution of activity within the source. An uncertainty budget is provided. The method was applied successfully in the intercomparisons. - Highlights: ► Modified radiochemical extraction procedure for 226Ra analysis in soil samples. ► Solid angle calculation method was used for detector efficiency. ► Modified procedure was successfully tested in intercomparisons.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2012.02.114

Additional details

Identifiers

DOI
10.1016/j.apradiso.2012.02.114;
PII
S0969-8043(12)00162-5;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
70
Journal Issue
9
Journal Page Range
p. 2260-2262
ISSN
0969-8043
CODEN
ARISEF

Conference

Title
18. international conference on radionuclide metrology and its applications
Dates
19-23 Sep 2011
Place
Tsukuba (Japan)

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.