Minimising contralateral breast dose in post-mastectomy intensity-modulated radiotherapy by incorporating conformal electron irradiation

  • 1. Department of Radiation Oncology, University Medical Center Groningen/University of Groningen, Groningen (Netherlands)

Description

Purpose: To assess the potential benefit of incorporating conformal electron irradiation in intensity-modulated radiotherapy (IMRT) for loco-regional post-mastectomy RT. Patients and methods: Ten consecutive patients that underwent left-sided mastectomy were selected for this comparative planning study. Three-dimensional conformal radiotherapy (3D-CRT) photon-electron dose plans were compared to photon-only IMRT (IMRTp) and photon IMRT with conformal electron irradiation (IMRTp/e). The planning target volume (PTV) was prescribed 50 Gy and included the chest wall and the internal mammary and supra-clavicular lymph node regions. It was attempted to minimise dose delivered to heart, lungs and contralateral breast (CB), while maintaining adequate PTV coverage. Results: All plans complied with objectives for PTV coverage. IMRTp/e eliminated volumes receiving ≥70 Gy (V70) that were present in 3D-CRT at the junction of photon and electron beams. Both IMRT strategies reduced heart V30 significantly below 3D-CRT levels. Mean heart dose with IMRTp/e was the lowest and was equal to that with 3D-CRT. Minimising heart dose with IMRTp resulted in irradiated CB volumes much larger than that with 3D-CRT. With IMRTp/e, CB dose was only slightly increased when compared to 3D-CRT. Mean lung dose values were similar for IMRT and 3D-CRT. With IMRT, lung V20 was smaller, whereas V5 values for heart, lung and CB were higher than those with 3D-CRT. Conclusions: Incorporation of conformal electron irradiation in post-mastectomy IMRTp/e enables a heart dose reduction which can only be obtained with IMRTp when allowing large irradiated volumes in the contralateral breast.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2009.12.015

Additional details

Identifiers

DOI
10.1016/j.radonc.2009.12.015;
PII
S0167-8140(09)00673-2;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
94
Journal Issue
2
Journal Page Range
p. 235-240
ISSN
0167-8140
CODEN
RAONDT

Conference

Title
10. biennial ESTRO conference on physics and radiation technology for clinical radiotherapy
Dates
30 Aug - 3 Sep 2009
Place
Maastricht (Netherlands)

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
41074397
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CHEST; ELECTRON BEAMS; HEART; IRRADIATION; LUNGS; LYMPH NODES; MAMMARY GLANDS; NEOPLASMS; PATIENTS; PHOTONS; PLANNING; RADIATION DOSES; RADIOTHERAPY
Descriptors DEC
BEAMS; BODY; BOSONS; CARDIOVASCULAR SYSTEM; DISEASES; DOSES; ELEMENTARY PARTICLES; GLANDS; LEPTON BEAMS; LYMPHATIC SYSTEM; MASSLESS PARTICLES; MEDICINE; NUCLEAR MEDICINE; ORGANS; PARTICLE BEAMS; RADIOLOGY; RESPIRATORY SYSTEM; THERAPY

Optional Information

Copyright
Copyright (c) 2009 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.