Screening mammogram in health center: medical audit for six years
- 1. Samsung Medical Center, Seoul (Korea, Republic of)
Description
To report the findings of a six-year medial oudit performed at our mammographic screening center, comparing those findings with the follow-up data stored at our hospital and at the Korea Central Cancer Registry. We analyzed the findings of 32,289 mammographic examinations of 25,541 women performed at our screening center between 1994 and 1999. For follow-up and outcome monitoring, the guideline of the American College of Radiology Breast Imaging Reporting and Data System (ACR BI-RADS) was used. All mammograms were categorized by means of BI-RADS, and cases in categories 0, 4 and 5 were followed up through a review of our hospital information system. To determine whether any cases were fales negative, we compared breast cancer patients registered in our medical record department and in the Korean Central Cancer Registry during the the study period, with women whose mammograms were interpreted as normal or benign at our screening center within a year prior to cancer diagnosis. The mean age of women enrolled in this study was 48.6 years, the years less than reported in the West. The recall rate was 6.2%. Among 256 women whose final assessment category was 4 or 5, breast cancer was diagnosed in 51. The cancer detection rate was 2.0/1,000 women; positive predictive value 1 (PPV1; PPV, based on abnormal findings at screening examination) was 2.5% of cases and PPV2 (PPV when biopsy or surgical consultation was recommended) was 2.0%. The most common mammographic finding was microcalcifications only (45%). The rate of minimal breast cancer, including invasive cancer less than 1 cm in diameter and ductal carcinoma in situ, was 72.5%. Node positively was 27%. Sensitivity was 85.0% based on the tumor registry of our institution's medical record department, and 78.5% based on the tumor registry of the Korea Central Cancer Registry. Specificity was 99.0%. In our study, the cancer detection rate ar screening mammography was 2.0/1,000 women. The rate of minimal breast cancer (72.5%) was very high but measurable sensitivity was 78.5%, somewhat lower than the ACR guideline of 85%. To improve the performance of screening mammography, appropriate interpretation of mammography and constant, follow-up and outcome monitoring are important
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Radiological Society
- Journal Volume
- 49
- Journal Issue
- 2
- Journal Page Range
- p. 137-142
- ISSN
- 0301-2867
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 34086968
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AUDITS; DIAGNOSIS; HEALTH SERVICES; HOSPITALS; MAMMARY GLANDS; NEOPLASMS
- Descriptors DEC
- BODY; BUILDINGS; DISEASES; GLANDS; MEDICAL ESTABLISHMENTS; ORGANS; SOCIAL SERVICES
Optional Information
- Notes
- 23 refs, 4 tabs