Quatrefoil Tube Support Plate Blockage Examination Magnetic Probe
Creators
- 1. Westinghouse Electric Germany, Mannheim (Germany)
Description
Preventive and Hard Steam Generator Chemical Cleaning are effective answers to this issue. Complementary, Magnetic Probe Examination is a way to quantify the cleaning efficiency by quantization of the deposit/blockage ratio before and after the cleaning process. The physical principle used in the magnetic probe is the attraction/repulsion force generated by the magnetic environment changes and applied to a permanent magnet. The probe is composed of a permanent magnet, a strength sensor and a signal amplifier. The acquired data are analyzed using a multilinear regression method apply on identified specific values. These values are considered, after laboratory test and studies, as essential representative parameters of the phenomena. By means of this technology, tube deposit and quatrefoil tube support plate blockage variations can be quantified and the efficiency of the cleaning process can be verified
Additional details
Publishing Information
- Publisher
- Pacific Nuclear Council
- Imprint Place
- La Grange Park (United States)
- Imprint Title
- Proceedings of the 18th Pacific Basin Nuclear Conference
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [1 p.]
Conference
- Title
- 18. Pacific Basin Nuclear Conference
- Acronym
- PBNC 2012
- Dates
- 18-23 Mar 2012
- Place
- Busan (Korea, Republic of)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 45032798
- Subject category
- S42: ENGINEERING; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CLEANING; EFFICIENCY; FLOW BLOCKAGE; MAGNETIC PROBES; PLATES; SENSORS; SIGNALS; STEAM GENERATORS; TUBES
- Descriptors DEC
- BOILERS; PROBES; VAPOR GENERATORS