Published November 16, 2000 | Version v1
Report Restricted

Hazard Evaluation for the Salt Well Chempump and a Salt Well Centrifugal Pump Design using Service Water for Lubrication and Cooling

Description

This report documents results of a preliminary hazard analysis (PHA) covering the existing Crane Chempump and the new salt well pumping design. Three hazardous conditions were identified for the Chempump and ten hazardous conditions were identified for the new salt well pump design. This report also presents the results of the control decision/allocation process. A backflow preventer and associated limiting condition for operation were assigned to one hazardous condition with the new design

Availability note (English)

Available from INIS in electronic form; Also available from OSTI as DE00805639; PURL: https://www.osti.gov/servlets/purl/805639-3cUR3N/webviewable/

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
87 p.
Report number
RPP--6954/Rev.1

Optional Information