Published 1976 | Version v1
Report Restricted

Modelling of Fission Product Distributions in the Primary Coolant Circuits of High Temperature Reactors

Description

A limited comparative study of the ADDICT and PAD codes for the desorption of fission product distribution in an HTR primary coolant circuit is described. The results of trial calculations are presented and compared with similar results obtained by alternate means. Suggestions for future work emphasise the improvement of descriptions of real coolant Circuit surfaces. (author)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
60 p.
Report number
DPTN--813

Optional Information

Notes
Document from Juelich Preservation Project; 14 refs., 7 figs., tabs.