Published March 1981 | Version v1
Report Open

Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979

Description

The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

12632829.pdf

Files (689.4 kB)

Name Size Download all
md5:ad5f6b62fd22cc88f2e40ef0f000284f
689.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
45 p.
Report number
AECL--7251