Can a radioactive implant induced x-ray emission (RIXE) technique be used to in vivo measurement of heavy elements

  • 1. Kanazawa Univ. (Japan). School of Medicine

Description

A radioactive implant induced x-ray emission (RIXE) technique was examined for the in vivo determination of heavy elements. By the use of 67Ga, 99mTc, 123I, 133Xe and 201Tl implant excitation sources, the excitation efficiency and x-ray attenuation were measured to reveal the potential pairs of source-heavy element of interest for in vivo elemental analysis by the RIXE technique. Detection limits for the RIXE in vivo analysis were evaluated according to Currie's criterion. Four pairs, 99mTc - Pb, 201Tl - I, 133Xe - Cd and 123I -Cd are potential. (author) 16 refs.; 5 figs.; 2 tabs