Limited angular range X-ray micro-Computerized Tomography: derivation of anatomical information as a prior for Optical Luminescence Tomography

Description

This thesis addresses the combination of an Optical Luminescence Tomograph (OLT) and X-ray Computerized Tomograph (XCT), dealing with geometrical constraints defined by the existing OLT system in which the XCT must be integrated. The result is an acquisition geometry of XCT with a 90 degrees angular range only. The aim is to derive an anatomical information from the morphological image obtained with the XCT. Our approach consisted i) in the implementation of a regularized iterative algorithm for the tomographic reconstruction with limited angle data, ii) in the construction of a statistical anatomical atlas of the mouse and iii) in the implementation of an automatic segmentation workflow performing the segmentation of XCT images, the labelling of the segmented elements, the registration of the statistical atlas on these elements and consequently the estimation of the outlines of low contrast tissues that can not be identified in practice in a standard XCT image. (author)

Abstract (French)

Cette these traite du couplage d'un tomographe optique par luminescence (LCT) et d'un tomographe par rayons X (XCT), en presence d'une contrainte sur la geometrie d'acquisition du XCT. La couverture angulaire du XCT est limitee a 90 degres pour satisfaire des contraintes spatiales imposees par le LCT existant dans lequel le XCT doit etre integre. L'objectif est de deriver une information anatomique, a partir de l'image morphologique issue du XCT. Notre approche a consiste i) en l'implementation d'un algorithme iteratif regularise pour la reconstruction tomographique a angle limite, ii) en la construction d'un atlas anatomique statistique de la souris et iii) en l'implementation d'une chaine automatique realisant la segmentation des images XCT, l'attribution d'une signification anatomique aux elements segmentes, le recalage de l'atlas statistique sur ces elements et ainsi l'estimation des contours de certains tissus a faible contraste non identifiables en pratique dans une image XCT standard. (auteur)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Original title (English)
Micro-tomographie par rayons X a angle limite: derivation d'une information anatomique a priori pour la Tomographie Optique par Luminescence

Publishing Information

Imprint Pagination
214 p.
Report number
FRNC-TH--13248

Optional Information

Notes
[250 refs.]; Available from the INIS Liaison Officer for France, see the INIS website for current contact and E-mail addresses