Published January 2004 | Version v1
Journal article

Application of Haselgrove method to attenuation calculation of flux from disk source and plane source

Creators

  • 1. NAIS Co. Inc., Nippon Advanced Information Service, Tokai, Ibaraki (Japan)

Description

This paper aims to supplement a tabulated table of widely-applied gamma-ray shielding formulas for a disk and plane sources overlooked at the time when renewed their function tables. It has been carried out with accuracy in 0.01% using a simple computer-aided program of the Haselgrove method prepared for the present study adopting a quasirandom number. This method has been proved to be effective and to take an executive time less than a minute per numerical calculation, and it is below one thousands of the crude Monte Carlo method's. (author)

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo)
Journal Volume
41
Journal Issue
1
Journal Page Range
p. 68-72
ISSN
0022-3131

Optional Information

Notes
14 refs., 2 figs., 5 tabs.