Published June 1988 | Version v1
Report

Development of exhaust filters to be used under extreme conditions

  • 1. Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Lab. fuer Aerosolphysik und Filtertechnik 2

Description

The investigations of stainless steel deep bed filters were continued under various working conditions. Measurement obtained with uranium as a test aerosol resulted in decontamination factors between 10.000 and 20.000 for particle sizes of 0.07 to 0.15 μm respectively. In order to investigate the influence of humidity and droplets, a special filter consisting of a pre-filter and a main-filter was used. Measurement of the decontamination factors obtained for various air velocities and simultanous spraying droplets did not show any influence on the deposition behaviour of the filter. At the clean air side no water could be detected. (orig./DG)

Additional details

Additional titles

Original title (German)
Entwicklung von Abluftfiltern fuer extreme Belastungen

Publishing Information

Imprint Title
Safety-oriented LWR research. Annual report 1987
Imprint Pagination
319 p.
Journal Page Range
p. 194-197.
Report number
KFK--4450

Optional Information

Notes
Imprint:Sicherheitsorientierte LWR-Forschung. Jahresbericht 1987.