Published September 2010 | Version v1
Report Open

The use of polyvinyl chloride dyed with bromo cresol purple in radiation dosimetry

  • 1. Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Radiation Technology

Description

In this work,the use of polyvinyl chloride (PVC) dyed with Bromo cresol purple in high dose radiation dosimetry has been studied according to the radio chromic change using visible spectrophotometry. The results show linear relationship between the relative absorbance (response) and the absorbed dose at the wavelength 417 nm in the range of 0-50 kGy. Dose rate, irradiation temperature, dye intensity have been investigated and found to be independent of the response. The effects of post-irradiation storage in dark and indirect daylight conditions on dosimetry performance are discussed. (Author)

Files

42109266.pdf

Files (576.4 kB)

Name Size Download all
md5:aa5cd72cb43c102ccfa81821a3a01e79
576.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
17 p.
Report number
AECS-R/RSS--895

Optional Information

Notes
15 refs., 6 figs.