Published October 15, 1983
| Version v1
Journal article
Optimization of cluster-counting transition radiation detectors
- 1. European Organization for Nuclear Research, Geneva (Switzerland)
- 2. AN SSSR, Moscow. Fizicheskij Inst.
- 3. AN SSSR, Moscow. Inst. Fiziki Vysokikh Ehnergij
Description
The optimal parameters for cluster-counting transition radiation detectors have been calculated. The results for electron/pion separation at energies proportional10 GeV and for kaon/pion separation at energies proportional100 GeV are given. (orig.)
Additional details
Publishing Information
- Journal Title
- Nucl. Instrum. Methods Phys. Res.
- Journal Volume
- 216
- Journal Issue
- 1/2
- Series
- Nucl. Instrum. Methods Phys. Res.
- Journal Page Range
- 105-111
- ISSN
- 0167-5087
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 15007020
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- BERYLLIUM; BORON; CARBON; ELECTRON DETECTION; FIBERS; FOILS; GEV RANGE 01-10; GEV RANGE 10-100; GEV RANGE 100-1000; KAON DETECTION; LITHIUM; OPTIMIZATION; PARTICLE DISCRIMINATION; PION DETECTION; POWDERS; RADIATION DETECTORS; TRANSITION RADIATION
- Descriptors DEC
- ALKALI METALS; ALKALINE EARTH METALS; CHARGED PARTICLE DETECTION; DETECTION; ELECTROMAGNETIC RADIATION; ELEMENTS; ENERGY RANGE; GEV RANGE; MEASURING INSTRUMENTS; METALS; NONMETALS; PARTICLE IDENTIFICATION; RADIATION DETECTION; RADIATIONS; SEMIMETALS