10 years of field experience with high-AVT water chemistry

  • 1. Siemens AG Unternehmensbereich KWU, Erlangen (Germany)

Description

At the end of 1981, the first German PWR started the commercial operation of using High-AVT secondary side chemistry. Up to the end of 1992 this plant generated approx. 105 millions of MWhrs at an average load factor of 87.2% without any steam generator tubing degradation. ECT inspections in all plants started under High-AVT chemistry, which did not show any tubing degradation caused by corrosion mechanisms. This clearly confirms that proper harmonization of material, design and water chemistry concepts of the secondary side systems consequently result in excellent steam generator performance. (authors). 5 figs., 9 tabs., 5 refs

Part of:
Chemistry in water reactors: operating experience and new developments. 2 volumes

Additional details

Additional titles

Original title (English)
La chimie dans les reacteurs a eau: retour d'experience et developpements nouveaux. Volume 2.

Publishing Information

Publisher
Societe Francaise d'Energie Nucleaire.
Imprint Place
Paris (France)
Imprint Title
Chemistry in water reactors: operating experience and new developments. Volume 2
Imprint Pagination
361 p.
Journal Page Range
p. 571-578.

Conference

Title
Operating Experience and New Developments.
Acronym
International Conference on Chemistry in Water Reactors
Dates
24-27 Apr 1994.
Place
Nice (France).

Optional Information

Notes
Imprint:La chimie dans les reacteurs a eau: retour d'experience et developpements nouveaux. Volume 2.