Published February 18, 1986 | Version v1
Report Open

Plasma measurements with the TMX-U E parallel to B end-loss-ion spectrometers

Description

Two E parallel to B end-loss-ion spectrometers (ELIS) are now making plasma measurements on Tandem Mirror Experiment-Upgrade (TMX-U). One instrument is mounted on each end of this open-ended tandem-mirror machine. These spectrometers observe plasma losses along magnetic-field lines. They operate reliably and with a minimum of attention during an experimental run. Their data, which are quickly acquired and analyzed, help guide the experimental sequence. The parallel electric and magnetic fields separate the end-loss ions according to mass (D+ and H+) and energy. Each spectrometer detects ions with an array of 128 flat collector plates that are made from copper-coated G10 epoxy fiberglass, normally used for printed-circuit boards. The ELIS diagnostic system produces a wealth of experimental information, including data on peak plasma potential, central-cell ion temperature, potentials in the thermal-barrier region, axial confinement and ion-end-loss plugging, energetic-electron losses, and hydrogen/deuterium concentrations. 6 refs., 5 figs

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE86008020.

Files

17063723.pdf

Files (190.6 kB)

Name Size Download all
md5:9fef5ea7d1e6ee5e1b1e5f2b8717da5f
190.6 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
15 p.
Report number
UCRL--93789

Conference

Title
High temperature plasma diagnostics.
Dates
9-13 Mar 1986.
Place
Hilton Head Island, SC (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
17063723
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ELECTRON TEMPERATURE; END EFFECTS; ION SPECTROSCOPY; MAGNETIC FIELDS; PLASMA DIAGNOSTICS; RECOMBINATION; TMX DEVICES
Descriptors DEC
MAGNETIC MIRRORS; OPEN PLASMA DEVICES; SPECTROSCOPY; TANDEM MIRRORS; THERMONUCLEAR DEVICES

Optional Information

Secondary number(s)