Plasma measurements with the TMX-U E parallel to B end-loss-ion spectrometers
Description
Two E parallel to B end-loss-ion spectrometers (ELIS) are now making plasma measurements on Tandem Mirror Experiment-Upgrade (TMX-U). One instrument is mounted on each end of this open-ended tandem-mirror machine. These spectrometers observe plasma losses along magnetic-field lines. They operate reliably and with a minimum of attention during an experimental run. Their data, which are quickly acquired and analyzed, help guide the experimental sequence. The parallel electric and magnetic fields separate the end-loss ions according to mass (D+ and H+) and energy. Each spectrometer detects ions with an array of 128 flat collector plates that are made from copper-coated G10 epoxy fiberglass, normally used for printed-circuit boards. The ELIS diagnostic system produces a wealth of experimental information, including data on peak plasma potential, central-cell ion temperature, potentials in the thermal-barrier region, axial confinement and ion-end-loss plugging, energetic-electron losses, and hydrogen/deuterium concentrations. 6 refs., 5 figs
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE86008020.Files
17063723.pdf
Files
(190.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:9fef5ea7d1e6ee5e1b1e5f2b8717da5f
|
190.6 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 15 p.
- Report number
- UCRL--93789
Conference
- Title
- High temperature plasma diagnostics.
- Dates
- 9-13 Mar 1986.
- Place
- Hilton Head Island, SC (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17063723
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ELECTRON TEMPERATURE; END EFFECTS; ION SPECTROSCOPY; MAGNETIC FIELDS; PLASMA DIAGNOSTICS; RECOMBINATION; TMX DEVICES
- Descriptors DEC
- MAGNETIC MIRRORS; OPEN PLASMA DEVICES; SPECTROSCOPY; TANDEM MIRRORS; THERMONUCLEAR DEVICES
Optional Information
- Secondary number(s)
- CONF-860324--6.