Published 2010 | Version v1
Book

Comparison of the German rule PAS1078 with MCNPX calculations

Creators

  • 1. AREVA NP GmbH - PEPA-G, Erlangen (Germany)

Description

The publicly-available German specification PAS1078 dating from January 2008 provides rules for the construction of structural radiation protection in the case of medical accelerator facilities for proton therapy. The major points of PAS1078 will be presented. Its method for the estimation of shielding thicknesses will be compared with the results of Monte Carlo calculations executed with MCNPXTM. Especially, it is aimed at the comparison of the shielding curves for various energies, their angular dependency, and the proposed approximation method for scattering through mazes. The results provide suitable knowledge concerning the precision of the PAS1078. (authors)

Part of:
Shielding aspects of accelerators, targets and irradiation facilities - Satif-10

Additional details

Publishing Information

Publisher
Organisation for Economic Co-Operation and Development - Nuclear Energy Agency
Imprint Place
Paris (France)
ISBN
92-64-03467-9
Imprint Title
Shielding aspects of accelerators, targets and irradiation facilities - Satif-10
Imprint Pagination
442 p.
Journal Page Range
p. 343-353

Conference

Title
10. workshop
Dates
2-4 Jun 2010
Place
Geneva (Switzerland)

Optional Information

Notes
8 refs.