Published July 1991 | Version v1
Journal article

Preoperative and postoperative evaluation of vascular diseases by 111In-oxine platelet scintigraphy

Description

111In-oxine platelet scintigraphy was performed on 20 patients with various vascular diseases to assess its clinical usefulness as a diagnostic procedure. Especially we evaluated its usefulness for thrombus formation after Ivaron sponge occlusion method (ISO method) and endotheliazation of prosthetic grafts. Negative image in thoracic false lumen was obtained 2 or 3 weeks after operation in all patients whose dissection was completely repaired by ISO method. It suggested early thromboexclusion in thoracic false lumen in which Ivalon sponge was implanted. Negative image was observed in two cases of saphenous vein graft and one of Dacron graft. The case of Dacron graft was examined 415 days after implantation. Negative result in this case would be accounted for by stabilized fibrin layer or good endothelial coverrage. The results suggest that 111In-oxine platelet scintigraphy is an appropriate technique for evaluating the encapsulation of prosthetic grafts and thromboexclusion after ISO method. (author)

Additional details

Additional titles

Subtitle (English)
Application to evaluation on healing process after Ivaron sponge occlusion method and graft implantation

Publishing Information

Journal Title
Myakkangaku
Journal Volume
31
Journal Issue
7
Series
Myakkangaku.
Journal Page Range
613-619
ISSN
0387-1126
CODEN
MIAKB