Quality assurance of GEM foils for the upgrade of the ALICE TPC

  • 1. Rheinische Friedrich-Wilhelms-Universität Bonn, Nussallee 14-16, D-53115 Bonn (Germany)

Description

With the planned upgrade of the ALICE Time Projection Chamber (TPC) the current readout technology will be replaced by a Gas Electron Multiplier (GEM)—based readout technology in order to allow for a continuous operation at high interaction rates up to 50 kHz. A stack of four GEM stages with non-standard field configuration was chosen to achieve a suppression of the ion backflow below 1%, while maintaining a good energy resolution below σ /  E = /unit[12]% for 55 Fe. A discharge probability of 10−10 for α-particles was confirmed for this low ion backflow field configuration. This is comparable to standard triple GEM detectors in low discharge settings. To upgrade all the Inner and Outer Readout Chambers of ALICE, 576 GEM foils will be needed. Only GEM foils that fullfill the highest quality criteria can be used. Therefore a quality assurance scheme has been developed that includes a large set of quality assurance measurements.