Published 1987
| Version v1
Report
Restricted
Investigations into the design of multi-terawatt magnetic switches
Description
Magnetic switches were successfully used for pulse compression in the CometII pulsed power module to deliver 2.7 MV and 3.7 TW to a 2 Ω matched load. However, the Comet switches suffered interwinding dielectric breakdowns and failed in <100 shots. Initial results from experiments on magnetic switch core insulations indicate that the insulation scheme used in the Comet switches was not optimal and better configurations exist. The Comet magnetic switch failures have been duplicated and studied on the Magnetic Switch Test Module (MSTM), a coaxial, 2 Ω PFL driven by a 600 kV Marx generator. The results of these experiments are discussed in detail
Availability note (English)
Available from NTIS, PC A02; 3 as DE87012014.
Files
Additional details
Publishing Information
- Imprint Pagination
- 5 p.
- Report number
- SAND--87-0172C
Conference
- Title
- 6. Institute of Electrical and Electronic Engineers pulsed power conference.
- Dates
- 29 Jun - 1 Jul 1987.
- Place
- Arlington, VA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19015303
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BREAKDOWN; CAPACITORS; DIELECTRIC MATERIALS; FAILURES; HIGH-VOLTAGE PULSE GENERATORS; PARTICLE BEAM FUSION ACCELERAT; PERFORMANCE TESTING; SWITCHES
- Descriptors DEC
- ACCELERATORS; ELECTRICAL EQUIPMENT; ELECTRONIC EQUIPMENT; ENERGY STORAGE SYSTEMS; EQUIPMENT; FUNCTION GENERATORS; MATERIALS; PULSE GENERATORS; TESTING
Optional Information
- Notes
- Paper copy only, copy does not permit microfiche production.
- Secondary number(s)
- CONF-870656--40.