Published April 1993
| Version v1
Journal article
Calculation and analysis of electric price in connection-grid of 2 x 600 MW PWR nuclear power plant
Description
Equation of electric price in connection-grid of PWR nuclear power plant was proposed, moreover, several values of fixed investment, annual interest rate and fund recycle period were assumed. Finally, the electric price in connection-grid was calculated, and from an analysis, when it is equal to 20-25 fen(RMB)/kw · h, the control values of fixed investment, annual interest rate and fund recycle period were determined
Additional details
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 14
- Journal Issue
- 2
- Journal Page Range
- p. 97-106.
- ISSN
- 0258-0926
- CODEN
- HDGOE6
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 25003683
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- CALCULATION METHODS; CAPITALIZED COST; CHARGES; ECONOMIC ANALYSIS; NUCLEAR POWER PLANTS; OPERATING COST; POWER GENERATION; PWR TYPE REACTORS; THEORETICAL DATA
- Descriptors DEC
- COST; DATA; ENRICHED URANIUM REACTORS; INFORMATION; NUCLEAR FACILITIES; NUMERICAL DATA; POWER PLANTS; POWER REACTORS; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS