Published March 7, 1975 | Version v1
Report Restricted

Back-pressure requirement for CACS core cooling

Description

A licensing topical report is presented to establish the minimum containment equilibrium back-pressure requirement in a standard 2000/3000 MW(t) HTGR for the core auxiliary cooling system (CACS) to perform a safe plant cooldown following a design basis depressurization accident (DBDA). The supporting analysis and data for CACS performance and those components which govern the acceptability of the postulated accident transient are presented. (U.S.)

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
Core auxiliary cooling systems

Publishing Information

Imprint Pagination
77 p.
Report number
GA-A--13325

Optional Information

Notes
General Atomic.
Secondary number(s)
GA-LTR--19.